Price 35000 INR/ Number

MOQ : 01 Number

Deuterium lamps Specification

  • Accuracy
  • High Stability (<0.1% drift/hr)
  • Voltage
  • 80-100 V (Ignition), 60-70 V (Operation)
  • Model No
  • Varies by Manufacturer
  • Frequency
  • 50/60 Hz
  • Automation Grade
  • Manual/Compatible with Automated Systems
  • Power Source
  • AC/Electronic Power Supply
  • Measurement Range
  • 160-400 nm (UV range)
  • Feature
  • Stable Output, Long Life, Low Noise
  • Temperature Range
  • Up to 350C
  • Core Components
  • Quartz Envelope, Cathode, Anode, Deuterium Gas
  • Equipment Materials
  • Quartz Glass, Metal Electrodes
  • Type
  • Deuterium Discharge Lamp
  • Usage
  • UV/VIS Spectrophotometer Source
  • Dimension (L*W*H)
  • Approx. 75 mm (L) x 25 mm (D)
  • Weight
  • Approx. 100-150 g
  • Radiation Intensity
  • Consistent across UV range
  • Lamp Life
  • Typically 1000-2000 Hours
  • Operating Current
  • 0.5-1 Amps
  • Ignition Current
  • 3-4 Amps
  • Wavelength Stability
  • Better than 0.05 nm/hour
  • Warm-up Time
  • Approx. 30 minutes
  • Base Type
  • Pin or Flange Mount (Varies)
  • Compatibility
  • Most Standard Spectrophotometers
  • Light Output
  • At least 0.3-0.8 mW at 250 nm
  • Operating Environment
  • 0-40°C, <85% RH
 
 

About Deuterium lamps



Capitalise on the praiseworthy performance and supreme reliability of our venerable Deuterium lamps, engineered for precision and longevity. Offering a lamp life of 1000-2000 hours and exceptional wavelength stability (better than 0.05 nm/hour), these lamps grant access to consistent radiation intensity across the UV spectrum, with light output from 0.3-0.8 mW at 250 nm. Constructed from quartz glass and metal electrodes, our lamps excel in demanding spectrophotometer applications, operating stably from 0-40C and accommodating various mounting options. Suitable for standard UV/VIS equipment, they present a compelling choice for laboratories seeking top-tier functionality.

Advantages and Application Areas of Deuterium Lamps

Deuterium lamps offer notable advantages such as highly stable UV output, long operating life, and low noise, making them indispensable in analytical technology. Their supreme accuracy ensures reliable measurements in UV/VIS spectrophotometry, high-performance liquid chromatography, and environmental analysis. The lamps' versatility in mounting options and wide operational temperature range enable their application across various laboratory settings and research environments, making them an ideal surface for scientific and industrial UV testing.


Supply, Export Market, and Packaging Details for Deuterium Lamps

Our deuterium lamps are stock ready for immediate distribution, allowing clients to reduce expenditure on delayed procurement. With supply ability scaled for small to large orders, we serve main export markets including Asia, Europe, and America. Lamps are securely packed in shock-resistant, compact containers to ensure safe transit. List price varies by model and configuration, offering flexibility for traders and laboratories seeking affordable, durable solutions from trusted Indian suppliers.


FAQ's of Deuterium lamps:


Q: How is the installation process for deuterium lamps in standard spectrophotometers carried out?

A: The installation process is designed to be straightforward, with most deuterium lamps compatible with standard pin or flange mount bases. Simply ensure the power is disconnected, secure the lamp in the designated mount, and follow manufacturer-specific guidelines.

Q: What benefits do Deuterium lamps provide in UV/VIS spectrophotometry applications?

A: Deuterium lamps provide consistent, stable output across the UV range with excellent wavelength precision, thereby enhancing the accuracy and reliability of repeated spectrophotometric measurements.

Q: When should Deuterium lamps be replaced for optimal performance?

A: Typically, replacement is recommended after 1000-2000 hours of operation to maintain praiseworthy spectral quality and stable light output, although usage environment and instrument requirements may affect actual lifespan.

Q: Where can these Deuterium lamps be utilized effectively?

A: These supreme Deuterium lamps are effective in laboratory environments, research institutions, environmental testing centers, and industrial quality control, wherever precise UV measurement is required.

Q: What is the main advantage of low drift and high wavelength stability in these lamps?

A: Low drift (<0.1% per hour) and superb wavelength stability ensure consistently accurate readings, reducing the need for frequent recalibration and minimizing measurement errors.

Q: How are Deuterium lamps packaged for export and what markets are they supplied to?

A: Lamps are securely housed in shock-resistant compact containers to guard against transit damage. They are exported mainly to Asian, European, and American markets by reputable Indian suppliers.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in HPLC spares Category

plunger seals

plunger seals

Price 34.0 INR / Number

Minimum Order Quantity : 01 Number

Model No : As per customer request or standard codes

Type : Plunger Seal

Automation Grade : Manual installation

Usage : Hydraulic and pneumatic applications

suction filters

suction filters

Price 1500 INR / Number

Minimum Order Quantity : 01 Number

Model No : SF Series / Custom markings

Type : Suction Filter

Automation Grade : Manual

Usage : Hydraulic and lubrication systems; pumps protection

HPLC peek nuts

HPLC peek nuts

Price 2400 INR / Box

Minimum Order Quantity : 1 Pack

Model No : Custom/Universal Fit for HPLC

Type : HPLC Peek Nut

Automation Grade : Manual

Usage : Used to connect tubing in HPLC systems

peek tubing

peek tubing

Price 950 INR / Meter

Minimum Order Quantity : 05

Model No : Refer to supplier

Type : Tubing

Automation Grade : Manual

Usage : Fluid transfer, analytical instrumentation, chemical processing



"We are looking for local inquiries form South India"
&
"We are dealing in bulk orders only."